#include <Arduino.h>
|
|
#include "MHZ19.h"
|
|
|
|
#define RX_PIN 0 // Rx pin which the MHZ19 Tx pin is attached to
|
|
#define TX_PIN 1 // Tx pin which the MHZ19 Rx pin is attached to
|
|
#define BAUDRATE 9600 // Device to MH-Z19 Serial baudrate (should not be changed)
|
|
|
|
MHZ19 myMHZ19; // Constructor for library
|
|
|
|
unsigned long getDataTimer = 0;
|
|
|
|
void setup()
|
|
{
|
|
Serial.begin(9600); // Device to serial monitor feedback
|
|
|
|
Serial1.begin(BAUDRATE); // (Uno example) device to MH-Z19 serial start
|
|
|
|
// myMHZ19.printCommunication(false, true);
|
|
myMHZ19.begin(Serial1); // *Serial(Stream) refence must be passed to library begin().
|
|
|
|
myMHZ19.autoCalibration(); // Turn auto calibration ON (OFF autoCalibration(false))
|
|
}
|
|
|
|
void loop()
|
|
{
|
|
if (millis() - getDataTimer >= 2000)
|
|
{
|
|
int CO2;
|
|
|
|
/* note: getCO2() default is command "CO2 Unlimited". This returns the correct CO2 reading even
|
|
if below background CO2 levels or above range (useful to validate sensor). You can use the
|
|
usual documented command with getCO2(false) */
|
|
|
|
CO2 = myMHZ19.getCO2(); // Request CO2 (as ppm)
|
|
|
|
Serial.print("CO2 (ppm): ");
|
|
Serial.println(CO2);
|
|
|
|
int8_t Temp;
|
|
Temp = myMHZ19.getTemperature(); // Request Temperature (as Celsius)
|
|
Serial.print("Temperature (C): ");
|
|
Serial.println(Temp);
|
|
|
|
getDataTimer = millis();
|
|
}
|
|
}
|